Saturday, January 3, 2009

AC Installed

So unit production at AAon built their tax deduction for me a few weeks ago, and I got it installed, charged and up and running. A few more software bugs to work out, and perhaps fiddle with the airflow rates a bit more for fine-tuning. But here sits my new 4-Ton condensing unit per my design (electrically speaking for the unit, and system design for the installation).
4-Ton split system with Air conditioning, Heat Pump (reverse air conditioner to provide indoor heating from 40+ degree's outdoor air temperature), Reheat (True de-humidification with a constant maintained indoor supply air temperature), Dual-Fuel (under 40-degree's outside air temperature, gas furnace takes over indoor-heating), Modulating Indoor ECM fan (200-600 Watts power draw), Modulating outdoor ECM Condenser fan (0-300 Watts Power draw, set to maintain head pressure and thusly use the least power necessary), Digital Scroll Compressor (10-100% true fully modulating compressing capability, 400-2,700 Watts usage based on indoor load). And oh yes, the unit is 15 SEER with a larger indoor coil and less efficient fan and compressor, this unit in particular calculates to between 17 and 24 SEER.


Here we are running the new refrigerant lines, I will be using one of the old refrigerant lines to pump out the condensate flow from the indoor coil (moisture being removed as humidity reduced) (which is quite sizeable in this region during the summer at around 1-2 gpm) onto the condensing coil to assist in reducing the need for the fan to run and compressor to work as hard due to condensing the refrigerant.
Note the different in size of the new 4-Ton unit and the old 3.5-Ton 10-SEER unit from ages past. The Condensing coil is meant for a 5-Ton, so its heat dissapation capabilities make the necessity of a fan almost inconsequential to operation.
Here is the brains behind the modulating capability of the compressor, temperature load controllers set to modulate capacity, one for heating and one for cooling. Currently they are set for an optimum of 70 degree's, thusly when cooling is required, if the indoor temperature is 70, it will operate at 10% capacity and energy usage, at 72.5 degree's it will be at 50%, and 75 degree's at 100%. Heating is the opposite with 50% being at 67.5 degree's and 100% being at 65 degree's. I still need to tie-wrap the wire looms to clean up the visual appeal.


Here is the controller that handles the dehumidification and blower motor control. I have to trick it a bit to utilize dual-fuel instead of electric heat and heat pump (electric heat strips being painfully inefficient and the worst source of home heating).